Off-grid twists invalidate an all-real clock-disorder lower bound

For every positive integer N, every β>0\beta >0 and every real twist ξ\xi with NξN\xi not an integer, there is 0≤λ<10\le \lambda <1 such that every joint thermodynamic limit D of the two-dimensional N-state clock disorder expectations with free boundary conditions along centered boxes satisfies D(r)≤λrD(r)\le \lambda ^{r} for each integer seam length r≥1r\ge 1. In particular ξ=1/(2N)\xi =1/(2N) defeats every positive power-law lower bound. Hence no threshold N1(β)N_{1}(\beta ) can make the printed all-real form hold for all ξ\xi in (0,1), even with an exponent depending on β\beta ,N and a positive prefactor depending on ξ\xi .

What was already known

Fröhlich and Spencer’s 1981 equation (7.5) gives a disorder power-law lower bound for sufficiently large clock order. The new repository distinguishes the valid grid restriction ξ=k/N\xi =k/N from the false all-real reading. The classical transition and its genuine clock-twist bounds remain prior human results.

How the result developed

  1. 12 Oct 2026 · Result reported [1]

    The original report describes the AI-assisted result.

Follow new evidence and revisions to this result.

Get email updates

Download contribution history

Contribution Assessment

AI involvementAI-centered
ImportanceModest
Human understandingFew

AI involvement

The authors set the scope and approved the statements. The pinned development records the off-grid clock-disorder obstruction among the project’s model-developed proof changes. Errors and gaps in the printed proofs were identified and repaired by arguments proposed by the models. The project used GPT-6 Luna, GPT-6.1 Sol, Claude Opus 5.5 and Claude Sonnet 5.5.

Importance

Identifies the missing grid restriction in an all-real reading of a classical disorder bound and proves an explicit obstruction.

Technical verification

The exact public Lean endpoint negates the all-real lower-bound quantifiers. Its provider uses an off-grid seam contraction, an exponential-versus-power comparison and the existence of a joint thermodynamic limit; the bridge identifies the internal model with the stated free-box clock observable. The repository reports kernel-checked proofs, no proof holes or custom axioms, and standard-axiom checks. The named source-facing definitions and statements were approved by the human authors. Checking is source-reported.

Possible mismatch: The Fröhlich–Spencer formalization report identifies a difference in the twist parameter. The printed lower bound ranges over real twists. The checked positive lower bound uses clock-grid twists ξ=k/n\xi=k/n. The project proves exponential decay off that grid.

Formal checking

The exact public Lean endpoint negates the all-real lower-bound quantifiers. Its provider uses an off-grid seam contraction, an exponential-versus-power comparison and the existence of a joint thermodynamic limit; the bridge identifies the internal model with the stated free-box clock observable. The repository reports kernel-checked proofs, no proof holes or custom axioms, and standard-axiom checks. The named source-facing definitions and statements were approved by the human authors. Checking is source-reported.

Checker
Lean4/Mathlib, as reported by Armstrong and Loher
Scope
Off-grid seam contraction and the exact negation of the all-real clock-disorder lower bound
Basis
Reported by the linked checker

Human understanding

Armstrong and Loher approved every exact formal definition and statement. The record does not document a completed human review of this new correction’s proof; the code and detailed repair arguments are attributed to agents.

View revision history
· addition

Added the research timeline.

· addition

Added a source excerpt documenting AI involvement.

· publication

Source-based omission review identified the retained central model-origin mathematical result and its exact scope.